- LIPO-ASPIRATION DEVICE
- LIPOSUCTION CANNULAS |
|
|
|
|
|
|
ASP Handle |
SYR Handle |
INF Handle |
INNIR-THD.Handle |
|
|
| TIP STYLES |
TIP NAME |
DIA
(mm) |
LENGTHS (Cm) |
CONNECTION TYPE |
7 |
9 |
15 |
26 |
32 |
36 |
Custom |
L |
S |
A |
|
Infiltration
Multiple
(IM) |
1,6 |
• |
• |
• |
|
|
|
|
• |
|
|
2,0 |
• |
• |
• |
• |
• |
|
|
• |
|
|
2,4 |
X |
X |
• |
• |
• |
X |
X |
• |
X |
X |
|
Infiltration
Single
(IS) |
1,6 |
• |
• |
|
|
|
|
|
• |
|
|
2,0 |
|
|
|
• |
|
|
|
• |
|
|
|
Three
Transverse
(MT) |
2,0 |
|
|
• |
• |
|
|
X |
X |
• |
• |
3,0 |
|
|
• |
• |
• |
• |
X |
X |
• |
• |
4,0 |
|
|
• |
• |
• |
• |
X |
|
• |
• |
5,0 |
|
|
• |
• |
• |
• |
X |
|
• |
• |
6,0 |
|
|
X |
• |
• |
X |
X |
|
• |
• |
|
Reverse
Triangle
(RT) |
2,0 |
|
|
• |
• |
|
|
X |
X |
• |
• |
3,0 |
|
|
X |
• |
• |
• |
X |
X |
• |
• |
4,0 |
|
|
X |
• |
• |
• |
X |
|
• |
• |
5,0 |
|
|
X |
• |
• |
• |
X |
|
• |
• |
6,0 |
|
|
X |
• |
• |
X |
X |
|
• |
• |
|
Forward
Triangle
(FT) |
3,0 |
|
|
• |
• |
• |
|
X |
X |
• |
• |
4,0 |
|
|
X |
• |
• |
X |
X |
|
• |
• |
5,0 |
|
|
X |
• |
• |
X |
X |
|
• |
• |
6,0 |
|
|
X |
• |
• |
X |
X |
|
• |
• |
|
Troops
(TT) |
3,0 |
|
|
• |
• |
• |
|
X |
X |
• |
• |
4,0 |
|
|
• |
• |
• |
X |
X |
|
• |
• |
5,0 |
|
|
• |
• |
X |
X |
X |
|
• |
• |
6,0 |
|
|
• |
• |
X |
X |
X |
|
• |
• |
|
Single Hole
(SH) |
3,0 |
|
|
• |
• |
X |
X |
X |
X |
• |
• |
4,0 |
|
|
• |
• |
X |
X |
X |
|
• |
• |
5,0 |
|
|
• |
• |
X |
X |
X |
|
• |
• |
6,0 |
|
|
• |
• |
X |
X |
X |
|
• |
• |
|
Platipus
(PL) |
2,0 |
|
|
• |
|
|
|
X |
X |
• |
• |
3,0 |
|
|
• |
|
|
|
X |
X |
• |
• |
4,0 |
|
|
• |
X |
|
|
X |
|
• |
• |
5,0 |
|
|
• |
X |
|
|
X |
|
• |
• |
6,0 |
|
|
• |
X |
|
|
X |
|
• |
• |
|
Fork-Dissector
(FD) |
3,0 |
|
|
• |
• |
X |
|
X |
|
|
|
4,0 |
|
|
• |
• |
X |
|
X |
|
|
|
| |
Custom Shape |
X |
X |
X |
X |
X |
X |
X |
X |
|
|
|
|
(X) Custom design (•) Standard design |
LIPOSUCTION CANNULA CODING SYSTEM
The cannula coding system is developed by trimed co. and aims to to make the order easlier.
The code consists of three letters and three nembers. The first letter indicates adapter type of the cannula Eg: S: for syringe, A: for aspirator type.
The second and third letters defines the hole pattern of the cannula. Eg: ReverseTriangle: RT, SingleHole: SH.
The second group is the number defined. The first number defines the diameter of the cannula. Second two numbers indicates the length of it. |
| |
|
|
| ADAPTER TYPE: |
HOLE PATTERN TYPE: |

STT 426 means syringe type, troops pattern, 4mm in diameter and 26 cm length cannula
|
|
| |
- SYRINGE GUN |
 |
| |
| - OTHER LIPOSUCTION INSTRUMENTS |
OTHER LIPOSUCTION INSTRUMENTS
|
|
Transfer Adapter- 01 |
|
|
Transfer Adapter- 50 |
|
|
PLS - Handle |
|
|
PLS - Adapter |
|
PLS - Adapter - 01 / 02 / 03
|
|
|
|
|